D2010M Multiplexer

D2010M
INTRINSICALLY SAFE ANALOG - TEMPERATURE MULTIPLEXER SLAVE UNIT (16 INPUTS)

Multiplexer Units D2010 can be installed in the field, close to input sensors, for data acquisition from Hazardous Area and connected to a Safe Area PLC/DCS or other devices, via 2 wire communication link and Interface Unit D2050M, saving wiring, cables and costs.
The Units are primarily intended for Hazardous Area acquisition of low level
signals from Thermocouples, RTDs, mV or mA sources.

SUPPLY   Via D2050M Interface Unit   CHANNELS   16   SERIES   D2000M

D2030M multiplexer

D2030M
INTRINSICALLY SAFE DIGITAL MULTIPLEXER SLAVE UNIT (32 INPUTS)

Multiplexer D2030M Units, can be installed in the field, close to input sensors, for data acquisition from Hazardous Area and connected to a Safe Area PLC/DCS or other devices, via 2 wire communication link and Gateway D2050M Unit, saving wiring, cables and costs.
The Units are primarily intended for Hazardous Area acquisition from contacts or proximity detectors.
D2030M scans all channels and stores all data in a memory buffer, where they can be rapidly accessed by the Modbus Gateway D2050M Unit.
Each Mux D2030M Unit accepts directly up to 32 input channels and is expandable to 128 channels by using four D2030M Units with a single Modbus Gateway D2050M
Unit.
Redundant communication is obtained by dual data/supply interface line.
Safety Parameters maintain compatibility with Gas Group II C even in
redundant mode.

SUPPLY   Via D2050M Gateway Unit.   CHANNELS   32   SERIES   D2000M

5700 Hart Modem

5700
HART® MULTIPLEXER MODEM 256 CHANNELS

The HART® Multiplexer Modem 5700 interfaces up to 256 smart devices (transmitters, I/P, proportional valves, etc…) in a HART® Network. Each device can be fully identified, configured and monitored by a remote PC running an FDT-based software package (PACTware™, etc...) through a dedicated Device Type Manager (DTM).
The module is intended to be mounted on the following Termination Boards:

• TB-D5001-HRT-003: to be used with G.M. International AI/AO Termination Boards;
• TB-D5001-HRT-004: to be used with DIN-Rail mounted barriers/isolators or direct field connections, for 4-20mA loop signal;
• TB-D5001-HRT-005: to be used with DIN-Rail mounted barriers/isolators or direct field connections, for 1-5V loop signal.

   *In order to communicate with the hardware, an RS232/RS485 converter should be connected to the serial port of the Host. The suggested converter is the D1061S.

 

The minimum required software tools, to be able to operate the HART® network, are the following:

• PACTware™ software
• HART® communication DTM
• HART® Mux 5700 DTM
• SWC5090 Configuration software

SEG, protection relays, relays, power, line, transmission line, power protection.